Home ProductsThree Phase Voltage Monitoring Relay

Phase Loss 3 Phase Control Relay 2C/O Contacts For 4 Wires Refrigerator

Certification
Good quality Single Phase Voltage Monitoring Relay for sales
Good quality Single Phase Voltage Monitoring Relay for sales
Customer Reviews
Товар пришел оперативно и в срок.

—— Gleb Yalymov

Great Seller. Fast delivery.

—— Sergey Budilov

спасибо получил очень быстро

—— Djakhangir Chariev

good quality, better than taiwan brand Anley and JVM. Good communication with seller.

—— Robert Ong

I'm Online Chat Now

Phase Loss 3 Phase Control Relay 2C/O Contacts For 4 Wires Refrigerator

China Phase Loss 3 Phase Control Relay  2C/O Contacts  For 4 Wires Refrigerator supplier
Phase Loss 3 Phase Control Relay  2C/O Contacts  For 4 Wires Refrigerator supplier Phase Loss 3 Phase Control Relay  2C/O Contacts  For 4 Wires Refrigerator supplier

Large Image :  Phase Loss 3 Phase Control Relay 2C/O Contacts For 4 Wires Refrigerator

Product Details:

Place of Origin: Wenzhou
Brand Name: Ginri
Certification: CE
Model Number: JVRD-380N

Payment & Shipping Terms:

Minimum Order Quantity: 20Pcs
Packaging Details: standard packing
Delivery Time: 2-5days
Payment Terms: L/C, D/P, T/T, Western Union
Supply Ability: 1000 pieces per month
Contact Now
Detailed Product Description
Input Circuit: L1,L2,L3 Or L1,L2,L3,N Rated Voltage: 220VAC,380VAC,400VAC,440VAC,460VAC,50/60HZ
Monitoring Function: Phase Sequence,phase Loss,overvoltage,undervoltage,phase Unbalance,neutral Loss Phase Unbalance Threshold: 15% Fixed
Delay Time For Overvoltage And Undervoltage: 5-8s Fixed Delay Time For Phase Loss,phase Unbalance: 1-2s Fixed

Phase Loss 3 Phase Control Relay 2C/O Contacts For 4 Wires Refrigerator

 

Phase sequence protector is a multi-function three-phase power system or three-phase power equipment monitoring and protection equipment.


The phase sequence protector can display the three-phase power supply voltage in real time, and can output through the relay when the power supply overvoltage protection, undervoltage protection, phase loss protection, unbalance protection, fault phase protection, PTC temperature protection, load side protection and other faults occur. The form provides the user with an alarm output and the contact control signal output by the protection circuit action, which functions as an alarm and protection. Sets three-phase voltage display, over-voltage protection, under-voltage protection, phase loss protection (phase-failure protection), voltage imbalance protection, phase sequence protection (wrong phase protection) in one, using a powerful microprocessor chip and non-easy Loss of storage technology, display using high-definition ultra-wide temperature Chinese liquid crystal, with full-featured, stable performance, intuitive display, easy operation.


1 .  High-precision : phase sequence protector uses a powerful microprocessor chip, the traditional technology uses AC sampling technology, voltage measurement accuracy of ± 1%, the new technology uses true RMS measurement technology, measurement is more accurate, the error is less than 1%, at the same time The three-phase power supply phase voltage values ​​can be displayed separately, which is equivalent to the functions of three voltage meters. ZHRV wide power frequency: phase sequence protector can be applied to 45 ~ 65HZ, to ensure universal use.


2 . Wide power supply voltage : The phase sequence protector can be applied to phase voltages of 150-300V (line voltage 250-500V), which greatly reduces the size of the phase sequence protector, making it easy for users to choose, and at the same time reducing the amount of spare parts funds.
Independent Normally Open, Normally Closed Output: The phase sequence protector adopts high-power double-group contact relays, which can independently control devices with different voltage levels, and is more widely used.


3 . Visual display : The phase sequence protector adopts a dedicated wide temperature and high-definition Chinese liquid crystal display, and displays the three-phase power supply phase voltage value during normal operation; in case of failure, it directly displays the cause of the fault in Chinese, and it can simultaneously display which phase fault and the fault The voltage value is very intuitive and it is easy to quickly determine the cause and location of the fault.


4 . Fault Record : The phase sequence protector adopts non-volatile storage technology. When overvoltage, undervoltage, phase loss, imbalance, or phase sequence fault occurs, the fault is recorded. Even if this product is completely powered off, fault information can be memorized to facilitate troubleshooting. 


5 . Installation method : The phase sequence protector base adopts rail type and has two M4 screw holes. It can be installed on HT35 rails or M4 screws. The two mounting methods are more flexible and convenient.


6 . Humanized Voltage Imbalance Protection : The phase sequence protector internally creates an optimized mathematical model that automatically adjusts the operating time based on the three-phase voltage unbalance and does not require user settings.

 

Features

  • Compact modular size
  • Three-phase monitoring of phase sequence.phase loss,over-and undervoltage and phase unbalance
  • Adjustable over and undervoltage threshold and delay time(For JVED-xxxW)
  • Neutral loss monitoring(for JVRN-xxxN&JVRD-NK)
  • Powered by the measuring circuit
  • 2C/O contacts
  • Max 5 LEDs for status indication

Protective Functions

  • Phase loss(Failure)
  • Phase sequence(Reversal)
  • Phase unbalance(Asymmetry)
  • Undervoltage
  • Overvoltage
  • Neutral loss

Applications

  • Pumps
  • Fans
  • Refrigeration units
  • Blowers
  • Motors
  • Compressors
  • Lifts,Elevators
  • Cranes
  • Mining excavators and conveyors

 

Model JVRD
Input circuit=Measuring circuit L1,L2,L3 or L1,L2,L3,N
Rated voltage(line voltage)

220VAC,380VAC,400VAC

440VAC,460VAC,50/60HZ

Monitoring functions

phase sequence,phase loss,overvoltage,undervoltage,phase unbalance

neutral loss

Phase unbalance threshold 15% fixed
Delay time for overvoltage and undervoltgae 5-8s fixed(0.1~10s adjustable for JVRD-xxxW)

Delay yome for phase loss,

phase unbalance,phase sequence

1-2s fixed
Reset time 0.5s fixed
indicators Phase sequence,phase loss,overvoltage,undervoltage,normal
Output contacts 2C/O(1C/O&1C/O&1NC for 3-phase 4 wire)
Contact capacity 6A,250VAC(resistiveload)
Degree of protection IP20
Working conditions -25℃~65℃,≤85%RH cnon-condensing
Mechanical durability 1000000 cycles
Dielectric strength >2KVA 1min
Weight 130g
Dimension(HxWxD) 79x23x79mm
Mounting Din Rail

 