Home ProductsMotor Protection Relay

Over / Under Current Motor Protection Relay 2 C/O Output Contacts With Fault Recording

Certification
Good quality Single Phase Voltage Monitoring Relay for sales
Good quality Single Phase Voltage Monitoring Relay for sales
Customer Reviews
Товар пришел оперативно и в срок.

—— Gleb Yalymov

Great Seller. Fast delivery.

—— Sergey Budilov

спасибо получил очень быстро

—— Djakhangir Chariev

good quality, better than taiwan brand Anley and JVM. Good communication with seller.

—— Robert Ong

I'm Online Chat Now

Over / Under Current Motor Protection Relay 2 C/O Output Contacts With Fault Recording

China Over / Under Current Motor Protection Relay 2 C/O Output Contacts With Fault Recording supplier
Over / Under Current Motor Protection Relay 2 C/O Output Contacts With Fault Recording supplier Over / Under Current Motor Protection Relay 2 C/O Output Contacts With Fault Recording supplier

Large Image :  Over / Under Current Motor Protection Relay 2 C/O Output Contacts With Fault Recording

Product Details:

Place of Origin: CHINA
Brand Name: GINRI
Certification: CE,CCC
Model Number: WDB-1Z

Payment & Shipping Terms:

Minimum Order Quantity: 10 Piece
Packaging Details: Voltage relay is standard seaworthy package,1pcs individual box or 5pcs in a middle box, 200pcs per carton. Base quotation is blank package. OEM design is acceptable
Delivery Time: 1-30 days upon order quantity
Payment Terms: L/C, T/T, Western Union,Paypal
Supply Ability: 20000Pcs per month
Contact Now
Detailed Product Description
Rated Voltage: 220VAC,380VAC ,50/60Hz Current Range: 1-10A,5-50A,10-100A,20-200A,80-400A,400-600A,600-800A
Protective Functions: Short-circuit, Locked-rotor, Overcurrent, Undervurrent, Phase Loss, Phase Unbalance,overvoltage,undervoltage, Earth Fault Optional Functions: RS-485 Communication Port 4-20 MA Analog Output
Indicators: LED Indicating Voltage,current,operation Status Output Contacts: 1 C/O For Trip,1 C/O For Alert

Over / Under Current Motor Protection Relay 2 C/O Output Contacts With Fault Recording

 

1. The motor is easier to burn the winding than in the past because of the continuous development of the insulation technology. In the design of the motor, both the increase of output and the reduction of the volume are required, so that the heat capacity of the new type of motor becomes smaller and smaller, and the overload capacity becomes weaker and weaker; Due to the increase in the degree of automation of production, the motor is often required to operate in frequent starting, braking, reversing, and changing loads, which imposes higher requirements on the motor protection device. In addition, the application of the motor is wider. Often working in harsh environments, such as humid, high temperature, dust, corrosion and other occasions. Coupled with the non-standard motor manufacturing, equipment management oversight. All this has caused today's motors to be more easily damaged than in the past, especially overloads, short circuits, phase loss, brooms, etc.

 

2. The traditional protection device has a poor protection effect. It is the traditional motor protection device that mainly includes fuses and thermal relays. Fuse is mainly used for short-circuit protection. The selection of fuse current needs to consider the starting current of the motor. Therefore, using a fuse alone to protect the motor is not desirable. Thermal relay is the most widely used motor overload protection device, but the thermal relay has low sensitivity, large error, poor stability and unreliable protection. This is precisely the fact that, although many devices have thermal relays installed, the phenomenon of motor damage that affects normal production still prevails. The traditional protection device has not yet been able to realize the motor wear monitoring, rotor eccentric monitoring products.

 

♦ Features

-- Separate structure,LED part panel mounted and CT part screw fixing

-- Built-in LED and keypad afford a precise,digital setting

-- Three-phase monitoring of short-circuit, locked-rotor,overcurrent, undercurrent, phase loss, phase unbalance,overvoltage,undervoltage

-- Earth fault (should couple with ZCT)

-- Fault recording

-- RS-485 communication port (optional)

-- 4-20 mA analog output (optional)

-- 2 C/O output contacts, one for trip,one for alert

 

 

♦ Protective Functions

-- Short-circuit

-- Locked-rotor

-- Overcurrent

-- Undercurrent

-- Phase loss

-- Phase unbalance

-- Overvoltage

-- Undervoltage

-- Earth fault

 

 

♦ Typical Applications

Pumps • Fans

Blowers • Motors

Compressors

 

♦ Technical data

 

Type WDZ-1Z WDZ-1F WDZ-1F2
Rated voltage 220VAC,380VAC ,50/60Hz
Current range 1-10A,5-50A,10-100A,20-200A,80-400A,400-600A,600-800A
Protective functions short-circuit, locked-rotor, overcurrent, undervurrent, phase loss, phase unbalance,overvoltage,undervoltage, earth fault
Optional functions

RS-485 communication port

4-20 mA analog output

Indicators LED indicating voltage,current,operation status
Output contacts 1 C/O for trip,1 C/O for alert
Contact capacity 3A 380VAC
Dimensions (H x W x D) 118×54×135mm 101×54×77mm(LED part) 101×54×77mm(LED part)
Mounting screw fixing LED part panel mounted and CT part screw fixing

LED part panel mounted

and CT part rail monting


 