Home ProductsCurrent Monitoring Relay

380VAC Digital Current Monitoring Relay , Phase Balance Relay 2 C/O Output Contacts

Certification
Good quality Single Phase Voltage Monitoring Relay for sales
Good quality Single Phase Voltage Monitoring Relay for sales
Customer Reviews
Товар пришел оперативно и в срок.

—— Gleb Yalymov

Great Seller. Fast delivery.

—— Sergey Budilov

спасибо получил очень быстро

—— Djakhangir Chariev

good quality, better than taiwan brand Anley and JVM. Good communication with seller.

—— Robert Ong

I'm Online Chat Now

380VAC Digital Current Monitoring Relay , Phase Balance Relay 2 C/O Output Contacts

China 380VAC Digital  Current Monitoring Relay , Phase Balance Relay 2 C/O Output Contacts supplier
380VAC Digital  Current Monitoring Relay , Phase Balance Relay 2 C/O Output Contacts supplier 380VAC Digital  Current Monitoring Relay , Phase Balance Relay 2 C/O Output Contacts supplier

Large Image :  380VAC Digital Current Monitoring Relay , Phase Balance Relay 2 C/O Output Contacts

Product Details:

Place of Origin: CHINA
Brand Name: GINRI
Certification: CE,CCC
Model Number: WDB-1FMT

Payment & Shipping Terms:

Minimum Order Quantity: 20Pcs
Packaging Details: Relay is standard seaworthy package,1pcs individual box or 5pcs in a middle box, 200pcs per carton. Base quotation is blank package. OEM design is acceptable.
Delivery Time: 1-30 days upon order quantity
Payment Terms: L/C, T/T, Western Union,Paypal
Supply Ability: 20000Pcs per month
Contact Now
Detailed Product Description
Power Supply Voltage: 220VAC,380VAC Operating Voltage Range: 220VAC:85-264V,380VAC:200-500V
Operating Voltage Frequency: 50/60Hz Operating Current Range: 1-10A,5-50A,10-100A,20-200A 80-400A,400-600A,600-800A
Protective Functions: Short-circuit, Locked-rotor, Overcurrent, Undervurrent, Phase Loss, Phase Unbalance, Overvoltage,undervoltage, Earth Fault Optional Functions: RS-485 Communication Port 4-20 MA Analog Output

380VAC Digital Current Monitoring Relay , Phase Balance Relay 2 C/O Output Contacts

 

The role of the motor protector is to give the motor a complete protection and control. In the motor there are overcurrent, undercurrent, phase failure, stall, short circuit, overvoltage, undervoltage, leakage, three-phase imbalance, overheating, grounding, bearing wear, When the stator and rotor are eccentric, the aging of the winding can be alarmed or protected.

 

Electronic motor protectors have been developed from transistors to integrated circuits. Microprocessor chips have been developed into thick-mode circuits and are generally classified into phase-failure protection, comprehensive protection (multi-function protection), temperature protection, and intelligent protection. Such protectors have the advantages of energy saving, sensitive operation, high precision, shock and vibration resistance, good repeatability, complete protection functions, and low power consumption.

 

1 .  The motor protector (motor protector) is based on the principle of detecting the change of the line current (including taking, positive sequence, negative sequence, zero sequence and overcurrent), and can detect phase failure or overload signal. In addition to the phase-failure protection function, it also has an overload and stall protection function.
2 .  Intelligent protection: The motor protection device integrates protection, telemetry, communication, and remote control to protect the motor from phase failure, overload, short circuit, undervoltage, overvoltage, and leakage, and it also has current and voltage display. Control, software self-diagnosis, call self-recovery, self-start sequence, fault memory, self-trim and remote alarm, flashing alarm before and after current and voltage faults during fault display, RS485 communication interface configuration, and computer networking. At the same time, it can monitor and monitor the functions of 256 motors.

 

♦ Features
-- Integrative structure or Separate structure
-- Built-in LED and keypad afford a precise,digital setting
-- Three-phase monitoring of short-circuit, locked-rotor,overcurrent, undervurrent, phase loss, phase unbalance,overvoltage,undervoltage
-- Earth fault (should couple with ZCT)
-- Fault recording
-- RS-485 communication port (optional)
-- 4-20 mA analog output (optional) unbalance,overvoltage,undervoltage
-- 2 C/O output contacts, one for trip,one for alert
 
♦ Protective Functions
-- Short-circuit -- Locked-rotor -- Overcurrent -- Undercurrent
-- Phase loss -- Phase unbalance -- Overvoltage -- Undervoltage
-- Ground fault
 
♦ Typical Applications
• Pumps • Fans • Blowers • Motors • Compressors
 
♦ Technical data

Type WDZ-1Z WDZ-1F WDZ-1F2
Rated voltage 220VAC,380VAC ,50/60Hz
Current range 1-10A,5-50A,10-100A,20-200A,80-400A,400-600A,600-800A
Protective functions short-circuit, locked-rotor, overcurrent, undervurrent, phase loss, phase unbalance,overvoltage,undervoltage, earth fault
Optional functions

RS-485 communication port
4-20 mA analog output

Indicators LED indicating voltage,current,operation status
Output contacts 1 C/O for trip,1 C/O for alert
Contact capacity 3A 380VAC
Dimensions (H x W x D) 118×54×135mm 101×54×77mm(LED part) 101×54×77mm(LED part)
Mounting screw fixing LED part panel mounted and CT part screw fixing

LED part panel mounted
and CT part rail monting

 
 
 
 
 
 
 
 
 
 
 
 
 
 
380VAC Digital  Current Monitoring Relay , Phase Balance Relay 2 C/O Output Contacts

Contact Details
Wenzhou Ginri Power Automation Co., Ltd.

Contact Person: sales

Tel: +8613757785251

Send your inquiry directly to us (0 / 3000)