Home ProductsCurrent Monitoring Relay

Pumps Under Current Protection Relay With Fault Recording 50/60 Hz WDB-1FMT

Certification
Good quality Single Phase Voltage Monitoring Relay for sales
Good quality Single Phase Voltage Monitoring Relay for sales
Customer Reviews
Товар пришел оперативно и в срок.

—— Gleb Yalymov

Great Seller. Fast delivery.

—— Sergey Budilov

спасибо получил очень быстро

—— Djakhangir Chariev

good quality, better than taiwan brand Anley and JVM. Good communication with seller.

—— Robert Ong

I'm Online Chat Now

Pumps Under Current Protection Relay With Fault Recording 50/60 Hz WDB-1FMT

China Pumps Under Current Protection Relay  With Fault Recording 50/60 Hz WDB-1FMT supplier
Pumps Under Current Protection Relay  With Fault Recording 50/60 Hz WDB-1FMT supplier Pumps Under Current Protection Relay  With Fault Recording 50/60 Hz WDB-1FMT supplier

Large Image :  Pumps Under Current Protection Relay With Fault Recording 50/60 Hz WDB-1FMT

Product Details:

Place of Origin: CHINA
Brand Name: GINRI
Certification: CE,CCC
Model Number: WDB-1FMT

Payment & Shipping Terms:

Minimum Order Quantity: 20Pcs
Packaging Details: Relay is standard seaworthy package,1pcs individual box or 5pcs in a middle box, 200pcs per carton. Base quotation is blank package. OEM design is acceptable.
Delivery Time: 1-30 days upon order quantity
Payment Terms: L/C, T/T, Western Union,Paypal
Supply Ability: 20000Pcs per month
Contact Now
Detailed Product Description
Indicators: LED Display,2LEDs Indicating Trip, Alert Output Type: 1 C/O For Trip,1 C/O For Alert
Operating Voltage Frequency: 50/60Hz Operating Current Range: 1-10A,5-50A,10-100A,20-200A
Protective Functions: Short-circuit, Locked-rotor, Overcurrent, Undervurrent, Phase Loss, Phase Unbalance, Overvoltage,undervoltage, Earth Fault Optional Functions: RS-485 Communication Port 4-20 MA Analog Output

Pumps Under Current Protection Relay With Fault Recording 50/60 Hz WDB-1FMT

 

First, the basic principles of selection

Today, there are no uniform standards for motor protection products on the market, and the model specifications are varied. Manufacturers in order to meet the different needs of users derive a lot of series of products, a wide range of types of users to bring a lot of inconvenience to the user selection, the user should fully consider the actual needs of motor protection in the selection, a reasonable choice of protection and protection To achieve a good protection effect, to improve the reliability of equipment operation, reduce unplanned parking, reduce accident losses.


Second, the basic method of selection
(a) Conditions related to selection:
The selection of motor protection has a reasonable matching relationship between the motor and the protector. The following provides several protection-related conditions and factors, which provide reference for the selection of the user.
1 . Motor: We must first understand the model specifications, motor functional characteristics, protection type, rated voltage, rated current, rated power, power frequency, insulation level and so on. These contents can basically provide reference for the user how to correctly use and maintain and select protectors.
2 . Environmental conditions: Mainly refers to normal temperature, high temperature, cold, corrosion, vibration, sand, altitude, and electromagnetic pollution.
3 , the use of motor: mainly refers to the characteristics of the requirements of mechanical equipment, such as fans, pumps, air compressors, lathes, oil field pumping units and other mechanical characteristics of the load.
4 . Control system: The control modes include manual, automatic, local control, remote control, independent stand-alone operation, and centralized production line control. The starting methods include direct, step-down, star delta, frequency sensitive rheostat, frequency converter, and soft start.
5 . Other aspects: The user's management of on-site production monitoring is more casual or rigorous, and the severity of non-normal downtime impact on production.
There are many relevant factors related to the selection of the protector, such as the installation location, power supply conditions, and the power distribution system, etc.; it is also necessary to consider whether the newly purchased motor protection configuration, or the motor protection upgrade, or the accident motor The perfection of protection, etc.; also consider the difficulty of changing the motor protection mode and the degree of impact on the production; need to comprehensively consider the selection and adjustment of the protector according to the actual working conditions at the site.

 

♦ Features
-- Integrative structure or Separate structure-- Built-in LED and keypad afford a precise,digital setting-- Three-phase monitoring of short-circuit, locked-rotor,overcurrent, undervurrent, phase loss, phase unbalance,overvoltage,undervoltage-- Earth fault (should couple with ZCT) -- Fault recording -- RS-485 communication port (optional) -- 4-20 mA analog output (optional) unbalance,overvoltage,undervoltage -- 2 C/O output contacts, one for trip,one for alert
 
♦ Protective Functions
-- Short-circuit -- Locked-rotor -- Overcurrent -- Undercurrent
-- Phase loss -- Phase unbalance -- Overvoltage -- Undervoltage
-- Ground fault
 
♦ Typical Applications
• Pumps • Fans • Blowers • Motors • Compressors
 
♦ Technical data

Type WDZ-1Z WDZ-1F WDZ-1F2
Rated voltage 220VAC,380VAC ,50/60Hz
Current range 1-10A,5-50A,10-100A,20-200A,80-400A,400-600A,600-800A
Protective functions short-circuit, locked-rotor, overcurrent, undervurrent, phase loss, phase unbalance,overvoltage,undervoltage, earth fault
Optional functions

RS-485 communication port
4-20 mA analog output

Indicators LED indicating voltage,current,operation status
Output contacts 1 C/O for trip,1 C/O for alert
Contact capacity 3A 380VAC
Dimensions (H x W x D) 118×54×135mm 101×54×77mm(LED part) 101×54×77mm(LED part)
Mounting screw fixing LED part panel mounted and CT part screw fixing

LED part panel mounted
and CT part rail monting

 
 
 
 
 
 
 
 
 
 
 
 
 
 
Pumps Under Current Protection Relay  With Fault Recording 50/60 Hz WDB-1FMT

Contact Details
Wenzhou Ginri Power Automation Co., Ltd.

Contact Person: sales

Tel: +8613757785251