Product Details:
Payment & Shipping Terms:
|
Measuring Circuit: | DC Circuit | Rated Voltage: | DC12V,DC24V,DC36V,DC48V |
---|---|---|---|
Monitoring Functions: | Overvoltage, Undervoltage | Trip Delay Time: | 0.1-15s Adjustable |
Indicators: | Normai, Trip | Output Contacts: | 2 C/O |
Batteries Undervoltage DC voltage monitoring relay 2 LEDs For Status Indication
Overvoltage refers to any voltage whose peak value is greater than the corresponding peak value of the maximum steady state voltage under normal operation. In engineering, it refers to any dangerous voltage that may cause damage to the equipment. Therefore, in the project, some overvoltages that are larger than the normal operating voltage but are insufficient to endanger the normal operation of the equipment are excluded.
When the motor is in normal operation, excessive reduction of the power supply voltage will cause the motor speed to drop or even stall. When the load torque is constant, the motor current will increase sharply and cause over-current. In addition, the voltage is too low will cause some electrical appliances to release, cause the control circuit to work abnormally, may have the accident. Therefore, it is necessary to cut off the power supply when the voltage drops to the minimum allowable value. This is undervoltage protection. Its task is mainly to prevent equipment from burning due to overload.
This Product DVRD is used for protect equipment for over and under voltage in single phase
We also have other product for protect the three phase or current and phase,if there have the need ,welcome to contact us ,we will try our best to help you
♦ Features
-- Compact modular size
-- DC circuit monitoring of over- and undervoltage
-- Adjustable over- and undervoltage threshold
-- Adjustable trip delay time
-- Powered by the measuring circuit
-- 2 C/O contact
-- 2 LEDs for status indication
♦ Protective Functions
-- Overvoltage
-- Undervoltage
♦ Typical Applications
• DC cabinet • Batteries
• Electric control system
♦ Technical data
Type | DVRD |
Measuring circuit | DC circuit |
Rated voltage | DC12V,DC24V,DC36V,DC48V |
Monitoring functions | overvoltage,undervoltage |
Voltage setting range |
Rated voltage Undervoltage overvoltage DC12V 10-14V 13-17V DC24V 20-28V 26-34V DC36V 30-42V 39-51V DC48V 40-56V 52-68V |
Trip delay time | 0.1-15s adjustable |
Indicators | Normal,Trip |
Output contacts | 2 C/O |
Contact capacity | 6A ,250VAC |
Dimensions (H x W x D) | 79×23×79mm |
Mounting | DIN rail |