Air conditions part Three Phase Voltage Monitoring Relay 2 C/O Output Contacts

China Air conditions part Three Phase Voltage Monitoring Relay 2 C/O Output Contacts supplier
Air conditions part Three Phase Voltage Monitoring Relay 2 C/O Output Contacts supplier Air conditions part Three Phase Voltage Monitoring Relay 2 C/O Output Contacts supplier

Large Image :  Air conditions part Three Phase Voltage Monitoring Relay 2 C/O Output Contacts

Product Details:

Place of Origin: CHINA
Brand Name: GINRI
Certification: CE,CCC
Model Number: JVRD-380W

Payment & Shipping Terms:

Minimum Order Quantity: 20Pcs
Packaging Details: Voltage relay is standard seaworthy package,1pcs individual box or 5pcs in a middle box, 200pcs per carton. Base quotation is blank package. OEM design is acceptable.
Delivery Time: 1-30 days upon order quatity
Payment Terms: L/C, T/T, Western Union,Paypal
Supply Ability: 20000Pcs per month
Contact Now
Detailed Product Description
Features: Adjustable Voltage Function: Phase Loss, Over Voltage, Under Voltage, Phase Unbalance
Rated Voltage: AC220V 380V 440V 460V 480V Output Contacts: 2C/O
Contact Capacity: 6A 250VAC Mounting: Din Rail

Air conditions part Three Phase Voltage Monitoring Relay under / over voltage adjustable

 

Due to short-circuit faults and other reasons, the line voltage will greatly reduce or even disappear within a short time. It will cause damage to lines and electrical equipment. For example, if the motor is worn down or blocked, an overcurrent of several times the rated current will be generated and the motor will be burned out. When the voltage recovers, the self-start of a large number of motors will cause the voltage of the motor to drop drastically and cause damage.


The voltage that causes the motor to wear out is called the critical voltage. When the line voltage is reduced to the critical voltage, the action of protecting the electrical equipment is called undervoltage protection. Its task is mainly to prevent the equipment from being burned due to overload. When the voltage of the circuit is lower than the threshold voltage, the protective device is called the loss of voltage protection. Its main task is to prevent the motor from starting.

 

Taking the power equipment on the line as an example, if the power cannot keep up, the voltage will decrease very much. According to the formula: P=U*I, U becomes smaller, I becomes larger, and U is smaller. The bigger will be.


For example, if U is U1 at the beginning, I=I1=P/U1 at this time. If the energy cannot keep up at this time, because the power P required by the power-consuming equipment is certain, then U will drop to 0.5U1. Current:
I=P/U=P/(0.5U1)=2*(P/U1)=2I1
In other words, if the voltage drops to half, then the current will be twice as high.
The problem arises in this case, according to the well-known Joule's law: heat Q=I*R*T
Any device on the line resistance R is certain, if, before the circuit heat is Q1 = I1*R*T, after the voltage U changes to 0.5U1, the current I is 2I1, at this time the line heat Q2 = I*R* T = (2I1) * R * T = 4 * I1 * R * T = 4Q1, that is, if the voltage is reduced by half, then the amount of heat generated by the line per unit time becomes four times.


It can be seen that the change of the heat generation per unit time of the device on the line is inversely proportional to the square of the change of the line voltage, so the more severe the voltage drop, the greater the heat generation of the device on the line. If the device heat accumulation on the line exceeds the thermal diffusion The speed of the device will become higher and higher, and it may cause accidents such as fire.
Therefore, it is necessary to set a critical voltage for the line. When the line voltage drops to this critical voltage, the line is cut off through a relay protection device or a device with similar function, thereby ensuring that the device devices on the entire circuit will not be burned out. This is called undervoltage protection.

 

 

♦ Technical data

Type JVRD-W
Measuring circuit L1,L2,L3
Rated voltage

220VAC,380VAC,440VAC,

460VAC,480VAC,50/60Hz

Monitoring functions

phase sequence,phase loss,overvoltage,

undervoltage,phase unbalance

Voltgae setting range ±5%~±20% adjustable
Indicators

phase sequence,phase loss,overvoltage,

undervoltage and normal

Output contacts 2 C/O
Contact capacity 6A,250VAC
Dimensions(H*W*D) 79*23*79mm
Mounting DIN Rail

Air conditions part Three Phase Voltage Monitoring Relay 2 C/O Output Contacts